D4MC-5020 Omron Limit Switch
D4MC-5020 Omron Limit Switch
Shape/Structure Enclosed Limit switches ctuator Panel mount roller plunger 12.7 dia. x 5
Stainless steel rollerFrequency 50/60 Hz Contact form SPDT Load General load Ratings (AC): Non-Inductive load Resistive load: 10 A at 125 VAC/10 A at 250 VAC/3 A at 480 VAC
Lamp load (NC): 3 A at 125 VAC/2.5 A at 250 VAC/1.5 A at 480 VAC
Lamp load (NO): 1.5 A at 125 VAC/1.25 A at 250 VAC/0.75 A at 480 VAC
Inductive load: 10 A at 125 VAC/10 A at 250 VAC/2.5 A at 480 VAC
Motor load (NC): 5 A at 125 VAC/3 A at 250 VAC/1.5 A at 480 VAC
Motor load (NO): 2.5 A at 125 VAC/1.5 A at 250 VAC/0.75 A at 480 VACRatings (DC): Non-Inductive load Resistive load: 10 A at 8 VDC/10 A at 14 VDC/6 A at 30 VDC/0.5 A at 125 VDC/0.25 A at 250 VDC
Lamp load (NC): 3 A at 8 VDC/3 A at 14 VDC/3 A at 30 VDC/0.4 A at 125 VDC/0.2 A at 250 VDC
Lamp load (NO): 1.5 A at 8 VDC/1.5 A at 14 VDC/1.5 A at 30 VDC/0.4 A at 125 VDC/0.2 A at 250 VDC
Inductive load: 6 A at 8 VDC/6 A at 14 VDC/5 A at 30 VDC/0.05 A at 125 VDC/0.03 A at 250 VDC
Motor load (NC): 5 A at 8 VDC/5 A at 14 VDC/5 A at 30 VDC/0.05 A at 125 VDC/0.03 A at 250 VDC
Motor load (NO): 2.5 A at 8 VDC/2.5 A at 14 VDC/2.5 A at 30 VDC/0.05 A at 125 VDC/0.03 A at 250 VDCInrush current NC: 30 A max.
NO: 15 A max.Ambient temperature Operating: -10 to 80 ℃ (with no icing) Ambient humidity 35 to 95 %
Permissible operating frequency Electrical: 20 operations / 1 minute max.
Mechanical: 120 operations / 1 minute max.Contact resistance (Initial value) 15 mΩ max. (initial value for the built-in switch whentested alone) Insulation resistance 100 MΩ min. (at 500 VDC) Dielectric strength Between each terminal of the same polarities: 1,000 VAC 50/60 Hz 1 min
Between each terminal and non-live-metallic part: 2,000 VAC 50/60 Hz 1 minDurability Electrical: 500,000 operations min.
Mechanical: 10 million operations min.Vibration resistance Malfunction: 10 to 55 Hz, 1.5 mm double amplitude, Contact opening: 1 ms max. at the free position and the total travel position. Shock resistance Destruction: 1,000 m/s2 max.
Malfunction: 100 m/s2 max. (1 ms max. at the free position and the total travel position)Degree of protection IP67
Operating Force (OF) Standard value 5.88 N max. Release Force (RF) Standard value 0.98 N min. Pre-Travel (PT) Standard value 1.6 mm max. Movement Differential (MD) Standard value 0.2 mm max. Over-Travel (OT) Standard value 5 mm min. Operating Position (OP) Standard value 33.4±1.2 mm
Stock
Ready Stock
₹500.00Price